Programmable Constant Temperature and Humidity Reliability Test Chamber
| Negotiable | 1 Set (MOQ) |
Simplewell Technology Co., Ltd.
Guangdong, China
Last Login Date:
Nov 23, 2024
Main Products:
Test Chamber, Test Equipment, Voc Emission Chamber, Formaldehyde Emission Chamber, Auto Test Equipment, Vehicle Test Chamber, Environmental Test Chamber
Product Description
Company Info
Basic Info.
Product Description
Programmable Constant Temperature and Humidity Reliability Test Chamber
Product purpose of Programmable Constant Temperature and Humidity Reliability Test Chamber
Constant temperature and moisture test chamber is also called constant temperature and humidity testing machine,
constant temperature and humidity experimental box, constant temperature machine or constant temperature humidity
chamber. It is a kind of equipment used to detect the performances of materials under all kinds of environments and
test the heat resistance cold resistance, cold resistance , dryness resistance, moisture resistance of all types of materials .
Such test chambers are suitable for testing the quality of products for the industries such as electronic industry, electrical
equipment, communication, instruments, vehicles, plastic products, metal, foods, chemical industry, building materials,
medical treatment, spaceflight and so on.
Technical Parameters of Programmable Constant Temperature and Humidity Reliability Test Chamber
| Model | STH150-20 | STH225-20 | STH408-20 | STH1000-20 | STH150-40 | STH225-40 | STH408-40 | STH1000-40 | STH150-70 | STH225-70 | STH408-70 | STH1000-70 | |||||||
| Volume (L) | 150 | 225 | 408 | 1000 | 150 | 225 | 408 | 1000 | 150 | 225 | 408 | 1000 | |||||||
| Inner size(mm) | W | 500 | 500 | 600 | 1000 | 500 | 500 | 600 | 1000 | 500 | 500 | 600 | 1000 | ||||||
| H | 600 | 750 | 850 | 1000 | 600 | 750 | 850 | 1000 | 600 | 750 | 850 | 1000 | |||||||
| D | 500 | 600 | 800 | 1000 | 500 | 600 | 800 | 1000 | 500 | 600 | 800 | 1000 | |||||||
| External size (mm) | W | 910 | 910 | 1010 | 1410 | 910 | 910 | 1010 | 1410 | 910 | 910 | 1010 | 1410 | ||||||
| H | 1580 | 1730 | 1830 | 1980 | 1580 | 1730 | 1830 | 1980 | 1580 | 1730 | 1830 | 1980 | |||||||
| D | 1073 | 1173 | 1373 | 1588 | 1073 | 1173 | 1373 | 1588 | 1073 | 1173 | 1373 | 1588 | |||||||
| Temperature range | -20°C~+150°C (180°C optional) | -40°C~+150°C (180°C optional) | -70°C~+150°C (180°C optional) | ||||||||||||||||
| Humidity range | 20%RH~98%RH/(20~85°C) | ||||||||||||||||||
| Temperature fluctuation | ±0.5°C | ||||||||||||||||||
| Temperature deviation | ±1.5°C | ||||||||||||||||||
| Humidity deviation | ±3.0%RH(≥75%);±5.0%RH(≤75%) | ||||||||||||||||||
| Warm-up time | 20°C~+150°C | 20°C~+150°C | 20°C~+150°C | ||||||||||||||||
| ≤50MIN | ≤50MIN | ≤50MIN | |||||||||||||||||
| Cooling time | +20°C~-20°C | +20°C~-40°C | +20°C~-70°C | ||||||||||||||||
| ≤45MIN | ≤70MIN | ≤90MIN | |||||||||||||||||
| Temperature & humidity regulating method | Balance temperature regulating (humidityregulating) mode | ||||||||||||||||||
| Working environment temperature | +5°C~+35°C | ||||||||||||||||||
| Material | Shell | Double side electrolysis plank and spraying plastics | |||||||||||||||||
| Inner shell | Stainless steel plate SUS304/2B | ||||||||||||||||||
| Thermal insulation | Polyurethane foam fiberboard | ||||||||||||||||||
| Regulator | Heater | Nicochrome fin heating tube | |||||||||||||||||
| Humidifier | Stainless steel armored heater humidifying the water pond (humidifying the water pond) | ||||||||||||||||||
| Fan | Centrifugal fan | ||||||||||||||||||
| Refrigerator | Mechanical compressor | ||||||||||||||||||
| Refrigerant | R404a | R404a /R23 | |||||||||||||||||
| Refrigerating mode | Mechanical binary cascade refrigeration (air cooling or water cooling) | Mechanical binary cascade refrigeration (air cooling or water cooling) | |||||||||||||||||
| Controller | Display | 7.0 inch TFT color LCD display | |||||||||||||||||
| Operation mode | Program operation fixed value operation | ||||||||||||||||||
| Setting mode | Multi language menu, input by touch screen | ||||||||||||||||||
| Program capacity | Number of editable program: 99 maximum; step : 999 steps; cycle number : 99 maximum | ||||||||||||||||||
| Setting range | Temperature: adjust according to the temperature range of the equipment; humidity:0% RH - 100% RH (such as humidity function of equipment) | ||||||||||||||||||
| Display resolution | Temperature: 0.01°C, time: 0.1min; humidity: 0.1% RH (temperature and humidity test equipment) | ||||||||||||||||||
| Input | Thermal resistance and thermocouple | ||||||||||||||||||
| Communication function ( purchasing) | RS-485 interface with local and remote communication function, monitoring software RS-485/RS-232 convertor, one COM interface and one USB interface occupying PC computer; connect 16 sets of equipment at most; and the maximum accumulated length of the cable is 800M . | ||||||||||||||||||
| Control mode | Anti-integration saturation PID | ||||||||||||||||||
| Curve recording function | RAM with battery protection it can save the setting value sampling value and sampling time of equipment; and the maximum recording time is 350 days (when the sampling period is 1.5 min) | ||||||||||||||||||
| USB function | It is equipped with 1 U-disk and software disk special for PC computer (applicable for simple and complex Chinese, English WINDOWS operation system); the test program is compiled by PC software and saved in U-disk; and then the test program is tuned out from the U-disk and saved in the controller; or the controller can be saved in u-disk; and then it is saved in PC computer to be analyzed and managed. The record data of the test curve recorded in the controller can be saved to U-disk; the test data/curve is directly displayed and printed by special software of PC computer; and the data is converted into format file. The recording data of the controller is as follows: two-circuit temperature - setting temperature and actually measured temperature; two-circuit humidity - setting humidity and actually measured humidity. | ||||||||||||||||||
| Auxiliary function | Fault alarm and reason, treatment prompt function power failure protection function, and upper and lower temperature limit protection function; Calendar timing function, ( automatic starting or automatic stop);self-diagnostic function | ||||||||||||||||||
| Water supply mode | Supply by water pump | ||||||||||||||||||
| Water storage tank | Handheld auxiliary water tank | ||||||||||||||||||
| Water quality | Resistance rate≤500Ωm | ||||||||||||||||||
| Power | AC380V±10%V 50HZ | ||||||||||||||||||
| Maximum current(A) | 12 | 12 | 12 | 22 | 14 | 14 | 18 | 25 | 20 | 20 | 22 | 38 | |||||||
| Installed capacity(KW) | 6 | 6 | 6 | 9 | 7 | 7 | 7 | 12 | 10 | 10 | 10 | 18 | |||||||
| Weight(KG) | 460 | 460 | 530 | 810 | 460 | 460 | 530 | 810 | 540 | 540 | 600 | 980 | |||||||
| Standard configuration | 1 observation window (transparent electro thermal film centre control glass); 1 Ф50mm wire hole in left and right; 2 sets of sample racks, floodlight; time accumulator( internal), 4 foot wheels; 1 power cable (3m long), 1 RS-485/232 interface; 1 control terminal of test power 1 USB interface and 1 U disk | ||||||||||||||||||
| Safety device | Residual-current circuit breaker, dry burning protector (for damp and heat only), water system protection device ( for damp and heat only), overheat protection of fan motor, fuse, overload short circuit protector of control loop, temperature limiting protector, under voltage protector of cooling water (for water cooling type only), over pressure, over current and overheat protection for compressor,phase sequence protection and over current protection of condensate fan for air cooling | ||||||||||||||||||
Reference Standards
* GB11158 Specifications for High Temperature Test Chambers;
*GB10589-89 Specifications for Low Temperature Test Chambers;
*GB10592-89 Specifications for Low/High Temperature Test Chambers;
*GB/T10586-89 Specifications for Thermal-humidity Test Chambers;
*GB/T2423.1-2008 Test Methods for Low Temperature Test Chambers;
* GB/T2423.2-2008 Test Methods for High Temperature Test Chambers;
* GB/T2423.3-2006 Test Methods for Thermal-humidity Test Chambers;
*GB/T2423.4-2008 Test Methods for Cyclic Damp Heat Tests;
*GB/T2423.22-2002 Test Methods for Temperature Variations;
*IEC60068-2-1.1990 Test Methods for Low Temperature Test Chambers;
*IEC60068-2-2.1974 Test Methods for High Temperature Test Chambers;
*GJB150.3 High Temperature Tests;
*GJB150.4 Low Temperature Tests;
*GJB150.9 Damp Heat Tests;
What we can support:
Sales director:Cindy
Phone: +86 186 7605 0580
